Branson Series 8000 Manual
. S83/85 Ultrasonic Generator A40-064 BRANSON Precision Processing Group 41 Eagle Road Danbury, CT 06-813-1961 (203) 796-0400 S83/85 Ultrasonic Generator A40-064 Rev 0 Page 1. Introduction Manual Change Information At Branson, we strive to maintain our position as the leader in ultrasonic cleaning and related technologies by continually improving circuits and components in our equipment. These improvements are incorporated as soon as they are developed and thoroughly tested. Limitations of Liability Branson’s liability, whether based on warranty, negligence, or other cause, shall not in any case exceed the cost of the equipment.
Description Branson's Series 8300 Ultrasonic tanks and generators provide the. Description Branson Series 8000 industrial cleaning. Owners Manuals. Branson Series 8500 Advanced Ultrasonic Generator offers a full range of features to meet any precision cleaning requirements. Used on a simple cleaning tank or in a.
In no case shall Branson be responsible for any consequential damages arising out of commercial loss. Transducer (elements) can hold a high voltage charge. Before troubleshooting or making repairs, discharge voltage by momentarily shorting pins A and B of the RF connector that plugs into the ultrasonic power supply. S83/85 Ultrasonic Generator Warnings A40-064 Rev 0 Page 5. Table of Contents S83/85 Ultrasonic Generator. 1 Introduction.3 Manual Change Information. 3 Warranty.
4 Warnings. 5 Table of Contents.6 List of Figures.8 About This Manual.13 General System Description. 13 1.6.1 Ultrasonic Generator Models.
Installing the I/O Board.84 7.1.3 I/O Board Input Signals.85 7.1.4 I/O Board Output Functions.86 OEM-I/O Board – STD-392-317.89 7.2.1 General.89 7.2.2 Kit Components.89 7.2.3 Installation.89 S83/85 Ultrasonic Generator Table of Contents A40-064 Rev 0 Page 7. Figure 3-4 Alignment of RF Plug. 25 Figure 3-5 Ultrasonic Tank Features.28 Figure 4-1 Operating US Switch S85.31 Figure 4-2 Operating US Switch S83.31 Figure 4-3 S85 Power Level Adjustment. 32 Figure 4-4 Power Adjustment.32 Figure 4-5 S85 Setting Power Modulation Mode. Figure 7-9 OEM-I/O Board Installation.91 Figure 7-10 OEM I/O Configuration.93 Figure 7-11 External Wiring Diagrams.94 Figure 7-12 OEM I/O Installation.95 Figure 7-13 Timer Option.96 Figure 7-14 Rack Mount Kit.97 S83/85 Ultrasonic Generator Table of Contents A40-064 Rev 0 Page 9. S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator Introduction A40-064 Rev 0 Page 11. About This Manual This manual contains instructions for installing, operating and maintaining S83/85 Ultrasonic Generators.
At the back of the manual you will find Appendices containing documentation including wiring schematics, plumbing schematics and assembly drawings. The following definitions apply in this manual: Note: Inconvenience only if disregarded - no damage or personal injury. Rack mount kit 101-063-503 I/O KIT OEM ON/OFF with status indication 101-063-561 I/O KIT FULL FEATURE, S8500 only STD-392-317 I/O KIT OEM ON/OFF with external interlock STD-410-901 TIMER 0-60 Mechanical Timer S83/85 Ultrasonic Generator Introduction A40-064 Rev 0 Page 14.
S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator Controls A40-064 Rev 0 Page 15. Power Level Adjustment port Allows manually setting the ultrasonic power level. AC Power Lights when the On/Off switch is on and the ultrasonic power supply has main AC power. S83/85 Ultrasonic Generator Controls A40-064 Rev 0 Page 16. 2.2.2 Adjustment Ports Figure 2-3 S8500 Adjustment Ports Item No.
Adjustment Port Function Sweep Width Adjusts the Sweep mode bandwidth. Power Level Adjusts the percentage of ultrasonic output power (20-100%). S83/85 Ultrasonic Generator Controls A40-064 Rev 0 Page 17. Power supply is in Standby mode when light is on.
OVER TEMP Annunciator lights when the ultrasonic power supply detects an excessive internal temperature. Power supply is in standby mode when light is on. S83/85 Ultrasonic Generator Controls A40-064 Rev 0 Page 18. Activates ultrasonic output power; LED is on when ultrasonics are on RESET Press when the LED is on to reset the ultrasonic power supply and turn the LED off. S83/85 Ultrasonic Generator Controls A40-064 Rev 0 Page 19. Displays product information, such as power level, frequency, and serial no. Serial number tag Displays serial number of the ultrasonic power supply.
Line Cord Connects ultrasonic power supply to AC power. S83/85 Ultrasonic Generator Controls A40-064 Rev 0 Page 20. S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator Installation A40-064 Rev 0 Page 21. Make sure to locate the ultrasonic power supply in an area free from water spray, splashing, and dripping.
Ground the ultrasonic power supply receptacle in accordance with local building codes. S83/85 Ultrasonic Generator Installation A40-064 Rev 0 Page 22. Place the ultrasonic power supply on a horizontal, flat surface top near the tank or transducer.
in an area away from any heat sources. Figure 3-1 Ultrasonic Power supply Dimensions S83/85 Ultrasonic Generator Installation A40-064 Rev 0 Page 23.
Branson 8000 Series Manual
Number of Elements 1012 - 40 Type of Immersible Transducer Immersible Size of Immersible Transducer Transducer Operating Frequency Number of Elements Note: Use 40 kHz transducer with 80, 120 and 170 kHz generators. S83/85 Ultrasonic Generator Installation A40-064 Rev 0 Page 24. Figure 3-4 Alignment of RF Plug Wire In Black Green Interlock Interlock Note: If the RF connector is not fully engaged by the knurl ring, the External Lock LED will light. S83/85 Ultrasonic Generator Installation A40-064 Rev 0 Page 25. Ultrasonic Tank Installation 3.7.1 Overview This section contains instructions for installing and operating a Branson ultrasonic tank with the S8000 ultrasonic power supply. The following tables contain model numbers and part numbers for unheated and heated ultrasonic tanks.
Table 4 Ultrasonic Tanks - Unheated Model Part No. Before installing, make sure that you turn off the ultrasonic power supply and disconnect your AC voltage source. Leave the ultrasonic power supply disconnected until you finish the installation. S83/85 Ultrasonic Generator Installation A40-064 Rev 0. If using a heated tank, plug in the heater. Plug RF cable into power supply. Turn on the ultrasonic power supply.
If using a heated tank, set the tank temperature. Place parts in basket. S83/85 Ultrasonic Generator Installation A40-064 Rev 0 Page 28. S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator Operation A40-064 Rev 0 Page 29. Remote position. Note: Before pressing the U/S control switch, make sure the ultrasonic power supply is powered up and the connection to the ultrasonic tank or immersible transducers is secure. S83/85 Ultrasonic Generator Operation A40-064 Rev 0 Page 30.
Figure 4-1 Operating US Switch S85 LED lit Press key Figure 4-2 Operating US Switch S83 LED lit Press key Press the U/S switch. The U/S power level will slowly ramp to the maximum setting determined by: (a) the power level setting or (b) the external DC control voltage (in Remote position). U/S LED lights. Turn the Power Level Adjustment Port to set the The U/S Power bargraph displays the Power Level.
Power level on the S85 generator. There is no display on the S83 generator. Figure 4-4 Power Adjustment Decrease Increase Power Level. To turn POW MOD off: press the U/S U/S Off switch.
Press the POW MOD switch. POW MOD mode inactive and the LED goes off. Press the U/S switch. Ultrasonic power supply returns to standard operating mode.
S83/85 Ultrasonic Generator Operation A40-064 Rev 0 Page 33. Sweep Mode Function 4.6.1 S83 Sweep Mode Sweep is always on at a fixed rate of 80 Hz and a bandwidth of +/- 700Hz. 4.6.2 S85 Sweep Mode Sweep Mode allows the ultrasonic power supply to operate above and below the operating frequency. The Rate switch is used in conjunction with Sweep Mode; refer to Sweep mode, for instructions on using the Rate function. Press the RATE switch to toggle between HI and LO (Low). Figure 4-9 Rate Switch Operation LED lit Press key S83/85 Ultrasonic Generator Operation A40-064 Rev 0 Page 35.
Press the RESET switch to turn the indicator off and allow the ultrasonics to be restarted. Removing AC power will also reset the fault condition. Figure 4-10 RESET Switch LED lit Press key S83/85 Ultrasonic Generator Operation A40-064 Rev 0 Page 36.
S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 37. System Installation Overview This section is for a customer who installs Branson custom tanks with Branson immersible transducers. All four types of immersible transducers – FC, CB, SB, and EB – mount on the sidewall or bottom of a custom ultrasonic tank. To connect an immersible transducer or group of immersible transducers to the power supply, you use one or more types of junction boxes. So throughout this manual, note that a 12-element immersible transducer contains 12 transducers, a 24-element transducer contains 24 transducers, and so on.
Figure 5-1 Transducer Elements Immersible Transducer Element S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 39. Insert the crimped connector into the hole and push in until seated at the bottom of the hole. Cover the crimp with RTV 102®. Figure 5-2 Junction Box Terminal Connections Hole Barrel Connectors Insulator Block S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 40. Cut away filler material. Slip rubber grommet over RF cable to point A, as shown. Figure 5-5 Task 3 Preparing an RF Cable (Task 3) Fold excess wire braid over the rubber grommet.
S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 41. Type EB − End Bulkhead Mounting fittings Type FC − Flexible Cable ID Engraving Mounting fitting (2 places) ID Engraving Type SB − Short Bulkhead Type CB − Cable Bulkhead S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 42. Flange−Mount Junction Box Weld Studs (4 places) Tank wall Master Junction Box EB/SB−Type Junction Box Refer to Configuration Diagrams which outline how the three styles of junction boxes are used. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 43. Mount the master junction box to the tank or surface. If mounting EB or SB immersible transducers, refer to the mounting instructions for EB or SB immersible transducers. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 44.
EB/SB Elem. S8XXX-12 S8XXX-12 POWER SUPPLY POWER SUPPLY RF Cable RF Cable Flange-mount EB/SB EB/SB Junction Box Junction Box Junction Box FC/CB FC/CB EB/SB EB/SB Elem. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 45. GENERATOR GENERATOR RF Cable RF Cable Flange-mount EB/SB EB/SB EB/SB Junction Box Junction Box Junction Box Junction Box FC/CB FC/CB FC/CB EB/SB EB/SB EB/SB Elem. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 46.
FC/CB EB/SB Immersible Immersible Transducers Transducers S8XXX-24 S8XXX-24 GENERATOR GENERATOR RF Cable RF Cable Flange-mount EB/SB EB/SB Junction Box Junction Box Junction Box FC/CB FC/CB EB/SB EB/SB Elem. S8XXX-24 S8XXX-24 GENERATOR GENERATOR RF Cable RF Cable Master EB/SB EB/SB EB/SB. FC/CB EB/SB Immersible Immersible Transducers Transducers S8XXX-36 S8XXX-36 GENERATOR GENERATOR RF Cable RF Cable Flange-mount EB/SB EB/SB EB/SB Junction Box Junction Box Junction Box Junction Box FC/CB FC/CB FC/CB EB/SB EB/SB EB/SB Elem. RF Cable Master S8XXX-36 S8XXX-36. EB/SB FC/CB Immersible Immersible Transducers Transducers S8XXX-48 S8XXX-48 GENERATOR GENERATOR RF Cable RF Cable Master EB/SB EB/SB EB/SB EB/SB Junction Box Junction Box Junction Box Junction Box Junction Box FC/CB FC/CB FC/CB FC/CB EB/SB EB/SB EB/SB EB/SB Elem. FC Immersible Models and Dimensions Table 6 FC Transducer Models Model Chrome Bright Annealed FC610-25-6 101-910-672 101-910-691 FC618-25-12 101-910-674 101-910-689 FC610-40-6 101-910-673 101-910-690 FC618-40-12 101-910-675 101-910-688 Figure 5-14 FC610/FC618 Mounting Dimensions S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 50. Measure, mark, and install four weld studs using the dimensions in Figure 5-10.
Position the immersible transducers over the weld studs through the flange holes. Route the flexible cable to the corresponding junction box. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 51.
Mount the immersible transducer to the tank or rack. Route the flexible cable to the corresponding junction box. Note: The min. Bend radius of the flexible cable is 4 inches in diameter. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0. ID Label (BLK) (BLK) (GRN/YEL) Wiring Diagram GND (GRN/YEL) RF+ (RED) RF− (BLK) Flexible Overbraid Hose from FC type Immersible Note: After installing, test grounds and continuity according to local codes.
S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 53. (BLK) (BLK) (GRN/YEL) Wiring Diagram GND (GRN/YEL) RF+ (RED) RF− (BLK) Flexible Overbraid Hoses from FC type Immersibles (2) Note: After installing, test grounds and continuity according to local codes. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 54. JUMPER GND (GRN/YEL) (BLK) (BLK) (GRN/YEL) RF− (BLK) RF+ (RED) Wiring Diagram SS Overbraid Flexible Conduit (3) To Immersibles Note: After installing, test grounds and continuity according to local codes. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 55. JUMPER GND (GRN/YEL) (BLK) (BLK) (GRN/YEL) RF− (BLK) RF+ (RED) Wiring Diagram SS Overbraid Flexible Conduit (4) To Immersibles After installing, test grounds and continuity according to local codes.
Note: S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 56. CB610-40-6 101-910-685 101-910-702 CB618-40-12 101-910-687 101-910-700 Figure 5-21 CB Type Immersible Transducer Dimensions MODEL CB618− XX − 12 SERIAL XX − XXXX − XX BRANSON ULTRASONICS CORPORATION DANBURY CT. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 57.
Attach the washer and jam nut to the fittings and tighten until the washer seats. Route the immersible transducer cable to the junction box (follow wiring instructions) or the ultrasonic power supply. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 58. Follow the instructions in the section Wiring Procedures, located at the front of the Immersible Installation Section. Attach the ground wire to the ground lug. When finished wiring, attach the junction box cover.
S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 59. ID Label − (BLK) (BLK) (GRN/YEL) Wiring Diagram GND (GRN/YEL) RF+ (RED) RF− (BLK) RF Cable from CB type Immersible Note: After installing, test grounds and continuity according to local codes. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 60. (BLK) (BLK) (BLK) (GRN/YEL) Wiring Diagram GND (GRN/YEL) RF+ (RED) RF− (BLK) RF Cables from CB type Immersibles (2) After installing, test grounds and continuity according to local codes.
Note: S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 61. GND (GRN/YEL) (BLK) (BLK) (GRN/YEL) RF− (BLK) RF+ (RED) Wiring Diagram RF Cables From CB−type Immersible Transducers To Immersibles Note: After installing, test grounds and continuity according to local codes. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 62. Transducers (RED) ID Label − − − − (BLK) (BLK) (BLK) GND (GRN/YEL) (BLK) (BLK) (GRN/YEL) RF− (BLK) RF+ (RED) Wiring Diagram RF Cables From CB−type Immersible Transducers To Immersibles S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 63. Figure 5-28 SB Type Immersible Dimensions 6' 3' 5' 10' MODEL SB618− XX −12 SERIAL XX − XXXX − XX 6' BRANSON ULTRASONICS CORPORATION DANBURY CT. 3' 3' 12' 18' S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 64.
Branson 8000 Series Manual
Attach the washer and jam nut to the fitting, and tighten. Connect the wires to the incoming RF cable or jumper from another immersible transducer. Follow the wiring instructions below. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 65.
5.10.3 Mounting and Wiring SB Type Immersible Transducers Figure 5-30 Wiring SB Junction Boxes RF cable to ultrasonic power supply EB/SB style junction boxes SB−Type immersible transducers S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 66. 101-910-697 Figure 5-31 EB Type Immersible Transducer Dimensions HOLE (4) 1/2' 6' 5' 1' 10' 2-5/8' 1/2' 11' 3/8' MTG HOLE (4) 1/2' 6' 5' 1' 18' 2-5/8' 1/2' 19' S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 67. Secure the Immersible to the bottom or wall with weldstuds, nuts and washers. Connect the wires to the incoming RF cable or jumper from another immersible transducer. Follow the wiring instructions. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 68.
Follow the instructions in the section Wiring Procedures, located at the front of the Immersible Installation Section. Attach the ground wire to the ground lug. When finished wiring, attach the EB/SB style junction box cover. S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 69. Transducer Fitting Fitting RF Jumper to SB/EB Box S8000 RF Cable To Power Supply RF Cable ID Label ALTERNATE USE Wiring Diagram Immersible Transducers (RED) (RED) − (BLK) (BLK) (GRN/YEL) S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 70. Fitting Fitting S8000 RF Cable RF Jumpers to To Power Supply SB/EB Box RF Cable ID Label Wiring Diagram Immersible Transducers (RED) (RED) (RED) − − (BLK) (BLK) (BLK) (GRN/YEL) S83/85 Ultrasonic Generator System Installation A40-064 Rev 0 Page 71.
S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0 Page 73. For a tank with the pump and filter option, inspect the filter cartridges and replace when necessary. Inspect the RF cable and line cord (heated units only) for damage.
Replace a damaged cable, and damaged line cord, or both. Refill the tank. S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0 Page 75. Incompatible load, power, or frequency Check model numbers of tanks or RESET LED’s connected to ultrasonic power supply. Immersible transducers connected to ultrasonic power supply.
Branson Series 8000 Ultrasonic
Refer to section 3 of the manual for more information. S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0 Page 76. Do a DC Hi Pot test: Connect DC Hi Pot positive red lead to pin; connect black negative lead to pin B. Apply 2500 VDC to the load.
If the test indicates leakage S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0 Page 77. Compare resistance values on your ohmmeter with the resistance values listed in Column 3. If the two values differ, the driver board assembly is bad. Check the assembly part number before calling for replacements.
S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0. 6.5.2 Minimizing Cavitation Erosion To reduce cavitation erosion:. Operate the ultrasonics only when actually cleaning parts.
Set the power level to the minimum setting that will produce clean parts. S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0 Page 79. 25-40kHz Driver Board 100-242-310 80-170 kHz Driver Board 100-242-369 On/Off Switch DPST 200-099-230 Power Oscillator Board 100-242-661 Control Bd. S8500 100-242-289 Control Bd.
S8300 100-242-339 RFI Bd. 230V 100-242-304 RFI BD 120V CPN-242-224 S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0 Page 80. Figure 6-3 Interconnection Diagram S83/85 Ultrasonic Generator Troubleshooting A40-064 Rev 0 Page 81. S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 82.
Full Feature Input/Output Board (101-063-561) The Input/Output (I/O) board kit is an accessory that allows you to operate the S83/S85 power supply remotely. The I/O board includes two ports on the back panel of the power supply: (a) a 2- position switch for selecting remote (I/O) or local (power supply) controls. Figure 7-3 Installing I/O Board Note: If you are replacing an I/O board from an 8000 Series Generator to an 8500 Series connection on oscillator board is either Pin J4 or J12. S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 84. Ultrasonics (U/S) ON/OFF Power Modulation Sweep Interlock Not Used Current Mode Control Input U/S Status Input Common Current Control Select 0-20ma – 4-20ma 0-10 VDC power control Current or Voltage Control Select S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 85. The I/O board contains a set pot labeled R86 that can be used to control ultrasonic power when using external control (i.e., PLC).
To enable this feature, jumper JP2 pins 1+2. While the jumper is in place you can no longer control power using J2 Pin 8. S83/85 Ultrasonic Generator Options A40-064 Rev 0. Figure 7-6 Discrete Outputs – Normally Open Contacts – 2 Points OUTPUT SPECIFICATIONS TYPE OF DEVICE RELAY CONTACT N.O. RELAY ISOLATION ISOLATION 5000VAC ISOLATION OUTPUT IMPEDANCE 30 mOHMS 24VAC OR VDC CONTACT RATING 5.0A S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 87.
TYPE OF DEVICE (0−20mA) OR (4−20mA) CURRENT SOURCE ISOLATION ANALOG ISOLATION 100 OHM − VOLTAGE OUTPUT OUTPUT IMPEDANCE 250 OHM − CURRENT OUTPUT 5mA − VOLTAGE MAX.OUTPUT SOURCE 20mA − CURRENT S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 88. I/O boards metal bracket. Secure the I/O board to the side panel by installing the supplied M3 x 25 screw, #6 flat washer, plastic spacer, M3 internal tooth washer and M3 nut. S83/85 Ultrasonic Generator Options A40-064 Rev 0.
To activate external lock, connect the terminal block pin 3 to pin 4. To deactivate, disconnect pin 3 from pin 4. The external fault and reset must be cleared by depressing the RESET button located at the front of the power supply. S83/85 Ultrasonic Generator Options A40-064 Rev 0. Figure 7-9 OEM-I/O Board Installation S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 91. M3 internal tooth washer and M3 nut.
Secure the I/O board’s ground wire ring tongue terminal to the power supply’s chassis M4 stud with the supplied M4 flat washer, M4 split washer and M4 nut in that order. S83/85 Ultrasonic Generator Options A40-064 Rev 0. SET: JP1 ON PINS 2 AND 3 TERMINAL 1 JP2 ON PINS 2 AND 3 TERMINALS 4 AND 3: RELAY OUTPUT TERMINALS 2 AND 1: U/S ACTIVATION JUMPERS GROUND WIRE CONNECTION S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 93.
24VDC source JP1 on pins 2 and 3 U/S on: Connect +24VDC JP2 on pins 2 and 3 to terminal 1, connect +24VDC common to terminal 2 Figure 7-11 External Wiring Diagrams S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 94. Figure 7-12 OEM I/O Installation S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 95. Release the knob. The generator will turn on and operate for the set number of minutes then turn off. Figure 7-13 Timer Option 6.75 REF 6.00 REF 2.00 3.12 4.00 8' OEM-I/O CABLE S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 96. The mounting slots on the bracket will fit a standard 19 inch rack.
Caution: Do not use the rack mount kit to support the generator. Use a shelf or support rails instead. Figure 7-14 Rack Mount Kit BRACKET S83/85 Ultrasonic Generator Options A40-064 Rev 0 Page 97. S83/85 Ultrasonic Generator A40-064 S83/85 Ultrasonic Generator Assistance A40-064 Rev 0 Page 99. Assistance Calling the Local Branson Representative If you have a problem call the local Branson field sales or service representative, who will know you, your needs and your applications. He may have a critical replacement part in stock that will return your machine to operation in the shortest possible time.
Special instructions (for example, “Hold at the airport and call”). Be sure to give a name and phone number. Call the Branson Parts Store at (203) 796-0575 or (203) 796-0330, OR If you know the part number(s), fax your order, including the information listed above, to (203) 796-0574. Returning Equipment When returning any part or equipment to the Branson factory, it must be accompanied by a Returned Goods Authorization (RGA) number.
This number is used to ensure proper handling and identification of your part or equipment and to expedite its repair and/or return. All returns or repairs should be sent to the Danbury, CT facility unless otherwise directed by Branson personnel. S83/85 Ultrasonic Generator Assistance A40-064 Rev 0 Page 104.
Download Read Online branson 2000 manual branson ultrasonic welder manual branson 900 series ultrasonic welder manual branson series 8500 ultrasonic generator manual branson series 8000 ultrasonic power supply branson ultrasonic cleaner service manual branson ultrasonic welder error codes The Series 7000 generator tank systems from EMERSON employ a separate tank and generator that makes up a two system ultrasonic cleaning unit. This system can deal with 12 to 36 elements per tank, and are available in either 25 or 40 kilohertz. Byterun builder for php crackle. Lighted panel switches allow each board to be controlled autonomously, DHA-1000 General Information. This DHA-1000 ultrasonic cleaner is a self-contained unit which consists of a powerful ultrasonic generator, a stainless steel cleaning tank and an array of durable industrial style 44 kHz transducers. These transducers provide increased cleaning power and ensure uniform cleaning activity.
22 Apr 2013 Series 7000. Ultrasonic Power Supplies. Troubleshooting To keep your Branson 8-7000 Cleaning System in proper working order, we recommend that generator is OFF. Line cord needs replacement.
Power fuse or circuit breaker tails while. Either one is underrated. Generator is on, but 2. Heater element needs Pick the size tank you need, add a generator and a basket - and you have a custom ultrasonic cleaning system. All Branson tanks come with inlet and outlet connections, making it easy to add filters, pumps, and other accessories.
We use Bright-Annealed 316L stainless throughout. This highly polished, rugged surface is Branson Ultrasonics Ultrasonic Generator System Accessories 1620 - No. 8 Mesh; For use with 22 gal. Tank Autoclaving, Sterilization and Lab Washers:Ultrasonic Cleaners. Branson makes no representations or warranties, either expressed or implied, with regard to the information in this manual. Since conditions of application are Ultrasonic generator. Transducers.
1.2.1 U?trasonic Generators. There are fourteen different models of the S-7000 ultrasonic generator. Seven of them. Branson 900 Series Manual. Ebook about Branson 900 Series Manual is available on digital and printed edition.
Download and read branson 900 series ultrasonic welder manual branson 900 series ultrasonic welder manual obtaining manuals and other series 7000 generator ultrasonic assembly systems 2000 series Branson Series 8300 Ultrasonic Generator offers a full range of features to meet any precision cleaning requirements. Used on a simple cleaning tank or in a fully integrated cleaning system, the Series 8300 will deliver precise cleaning quickly, consistently, and cost effectively. Request Quote.
Specifications; Features 1.2.1. When used in accordance with written instructions and under normal operating conditions, Branson manufactured products are guaranteed to be free from defects in material and workmanship for ONE YEAR. In addition, Branson Series 8000 Power. Supplies are guaranteed for TWO YEARS.